Cooling Column, Type 5

Cooling Column, Type 5 Manufacturers & OEM Suppliers from India

Engineering Lab Equipment Thermal Training Equipment

Cooling Column, Type 5

Product Code LTEKCTLB-TTE60-004

Description & Specification

Cooling Column, Type 5

Technical Specifications

The cooling tower body of the test bench is a cylindrical structure made of transparent and observable acrylic material, and a variable area built-in packing is designed in the middle to compare and observe the cooling capacity of different layouts of packing. The air enters the cylinder from the bottom and flows upward; the inlet section and outlet section are connected with a differential pressure gauge to measure the pressure loss. The middle packing tray can be adjusted to change the heat exchange area.

Features:
The import and export data of the cooling tower can be digitally displayed by instruments;
cooling tower type 2 can be connected and compared with other types of cooling towers;
The data of each point of the workbench cycle can be displayed on the PC through a USB device;

Preview Content:
The main factors affecting heat and moisture transfer
In a cooling tower under normal operation, the main factors affecting the heat transfer process of the cooling tower are the inlet air wet bulb temperature (absolute saturation temperature), inlet water temperature, air volume, and circulating water volume. The water volume and the air volume The ratio of is called the water-to-air ratio.
Influence of water volume:
The outlet water temperature increases with the increase of the inlet temperature and outlet temperature of the circulating cooling water. The temperature difference decreases, so the cooling capacity of the cooling tower decreases. Control other factors unchanged, only change the water volume. As the circulating water volume of the cooling tower increases, the amount of air contacted by the unit water volume decreases, and the heat exchange decreases. 
The influence of air flow:
Control other factors unchanged, only change the air flow rate. As the air volume increases, the amount of air contacted by the unit water volume increases, and the cooling tower’s heat dissipation capacity increases.
The influence of inlet water temperature:
Control other factors unchanged, only change the inlet water temperature, the heat exchange power of the entire heat exchange process increases with the increase of the inlet water temperature, which represents the stronger the heat dissipation capacity of the cooling tower.
The influence of the inlet air wet bulb temperature:
Control other influencing factors unchanged (inlet water temperature, water volume, air volume), and the heat transfer power (enthalpy difference) of the entire heat transfer process decreases with the increase of outdoor air wet bulb temperature, which means that the cooling tower’s heat dissipation capacity is worse.
Why choose LTekOnline

Trusted Cooling Column, Type 5 Manufacturer & Supplier

LTekOnline are the manufacturers of Cooling Column, Type 5 used to demonstrate engineering principles in Engineering Colleges, Engineering Schools, and Thermal Training Equipment for Engineering Teaching Lab in Universities. We supply Cooling Column, Type 5 to TVET institutes, vocational training centres, polytechnics and research labs across more than 90 countries, with quality testing technology, comprehensive operation manuals and full after-sales support.

  • Manufactured to international standards
  • Detailed operation & experiment manuals
  • Turnkey lab installation & training
  • Worldwide shipping & on-site support
20000+ Lab Products
90+ Countries Served
2000+ Turnkey Projects

Need a Quote for Cooling Column, Type 5?

Get a custom quote, technical datasheet, or schedule a virtual demo with our lab equipment specialists. We respond within 24 hours.